Stop Blamingthe Baricity

The real culprits behind failed obstetric spinals, and the moves that salvage the case

Lecture re-echo · Dr. Edgard M. Simon, FPSA, MSOA, MHSA

Presented by Nicole Nathalie Laranang, RN, MD

What we will cover

  1. 1The problemA familiar case, and how often failure happensSlides 3–4
  2. 2Five points of failureNeedle, dose, spread, measurement, the drugSlides 5–10
  3. 3What to doA checklist, a safe rescue, a fair investigationSlides 11–13
  4. 4Take-homeFour messages to bring back to the ORSlide 14
Stop Blaming the Baricity|Lecture re-echo|Roadmap2 / 15

A familiar scenario

T4T6T8T10 Right side Pain Left side Numb
One-sided block: only the left side is numb
Patient
32 y, G2P1, BMI 34
Procedure
Elective repeat cesarean
Puncture
L3–4, 25G pencil-point
CSF
Clear, free flow, single pass
Dose
2.2 mL 0.5% heavy bupivacaine + fentanyl
Position
Supine, left lateral tilt

First suspicion in the room?

“The bupivacaine was weak.”
“Bad batch again.”
“It’s the brand we’re using.”

We return to the drug last, and only on the evidence.

Stop Blaming the Baricity|Lecture re-echo|The problem3 / 15

How often does this happen?

Reported rates of failed or inadequate spinal block, across published series

0%5%10%15%20% Prospective obstetriccohort (n = 275) Pooled publishedrange, upper end Elective cesarean,systematic review Complete failure,experienced hands Prospective obstetric cohort (n = 275): 19.6% Pooled published range, upper end: 17.0% Elective cesarean, systematic review: 7.0% Complete failure, experienced hands: 0.8% 19.6%17.0%7.0%0.8%

Source: series cited in the lecture, including Fettes et al., Br J Anaesth 2009, and Plaat et al., Anaesthesia 2022.

Stop Blaming the Baricity|Lecture re-echo|The problem4 / 15

Five points of failure

Fettes’ sequential framework: the drug must survive every step, in order

Lumbar puncture

1

Needle in the right space?

Preparation and injection

2

Full dose delivered?

Spread through CSF

3

Reached the right height?

Action on nerve tissue

4

Drug potent at the target?

Assessment of block

5

Measured correctly?

Only one of these five is the ampule. Four are ours.

Our techniqueThe drug

Stop Blaming the Baricity|Lecture re-echo|Five points of failure5 / 15
1

The needle wasn’t where we thought

Partial or transient intrathecal placement is the most common single mechanism

Epidural space Dura CSF Opening fully inside CSF Full dose reaches CSF Opening straddles the dura Part of the dose is lost Drug in CSFDrug lost to epidural space
  1. Partial placement

    The opening straddles the dura: part of the dose reaches CSF, part does not.

  2. Needle moves as the syringe goes on

    Shifts between aspiration and injection are documented, and probably underestimated.

  3. Multiple attempts or a bloody tap

    Both are linked to failure; a bloody tap roughly doubles the odds.

  4. No re-aspiration after injection

    Aspirate before and after, to confirm the tip stayed in CSF.

Stop Blaming the Baricity|Lecture re-echo|Five points of failure6 / 15
2

Between the ampule and the CSF

A correct ampule can still deliver an incorrect dose

Drawn volume Hub + needle dead space drug left behind

Dead space

Drug stays in hub and needle

Leak

At the hub or syringe joint

Incomplete draw-up

Ampule not fully withdrawn

Less than the intended 10 mg reaches the CSF

Stop Blaming the Baricity|Lecture re-echo|Five points of failure7 / 15
3

The variable we cannot see

Lumbosacral CSF volume best predicts block height, and varies two- to three-fold

Normal CSF volume Reduced CSF volume Epidural fat and veins 28 mL Predictable spread 14 mL Higher, less predictable
  • Obesity

    Abdominal pressure and epidural fat compress the thecal sac.

  • Term pregnancy

    Engorged epidural veins and aortocaval compression reduce CSF volume.

  • Position and tilt

    Hyperbaric spread follows tilt, wedge, hip height and time to supine. Lordosis alters pooling.

  • Anatomy (uncommon)

    Scoliosis, prior instrumentation, dural ectasia, arachnoid septa.

Stop Blaming the Baricity|Lecture re-echo|Five points of failure8 / 15
4

Some failures are measurement errors

Each sensation blocks to a different height, and the surgeon tests touch

T2T4T6T8T10 Cold: block to T2 Pinprick: block to T4 Touch: block to T6 ColdPinprickTouch what the surgeon tests

Cold at T4 ≠ adequate to touch

  1. Tested too early

    Onset takes time. Testing too soon invites an unnecessary, dangerous repeat dose.

  2. Tested the wrong sensation

    Document cold AND touch, to a set dermatome, before knife to skin.

  3. Nobody asked the patient

    Neither obstetricians nor anesthesiologists reliably detect pain during surgery without asking.

Pain during cesarean has overtaken awareness under GA as the most common successful obstetric claim.

Stop Blaming the Baricity|Lecture re-echo|Five points of failure9 / 15
5

And what about the drug?

Test the accusation like any hypothesis: look at the pattern

If it were a bad batch

Failures cluster in time, place and lot number

What we actually see

Failures scatter across years, hospitals and operators

A defective lot leaves a fingerprint. This failure pattern has none.

Stable. Bupivacaine is chemically stable within its shelf life.

Same stock works. It succeeds in the same room, on the same day.

Never tested. The accusation has never been formally tested.

Stop Blaming the Baricity|Lecture re-echo|Five points of failure10 / 15

Before you blame the ampule

Five questions, answered in order, before the next dose is drawn

  1. Dose

    Was the full intended dose delivered?

    Volume, concentration, dead space, leak

  2. Placement

    Free CSF before AND after injection?

    Single pass? Clear, not bloody?

  3. Position

    Was the patient positioned as intended?

    Tilt, wedge, hip height, time supine, movement before fixation

  4. Assessment

    Was the block measured properly?

    Cold and touch, documented dermatome, adequate interval

  5. Patient

    Is there a patient-side explanation?

    BMI, anatomy, prior spinal surgery, previous failed block

Only when all five are answered does “bad drug” become a legitimate hypothesis.

Stop Blaming the Baricity|Lecture re-echo|What to do11 / 15

Managing the inadequate block

Decision points, and the one maneuver that causes a total spinal

Block inadequate

Before incision

Block clearly absent

A repeat spinal is reasonable, but reduce the dose. Never repeat a full dose blindly.

Before incision

Low or patchy block

Adjust position, allow time. Epidural top-up if a catheter is in place. Reassess with touch.

After incision

Pain during surgery

Ask directly, and keep asking. IV supplement, infiltration, then GA without delay.

Repeating a full dose after a partly working spinal is how total spinals happen.
Recognize early, dose low, escalate without shame.

Stop Blaming the Baricity|Lecture re-echo|What to do12 / 15

What would change my mind

If a lot is genuinely suspect, the answer is an investigation

  1. Record

    Lot number, expiry, quantity, date and time

  2. Quarantine

    Set aside the remaining stock from that lot

  3. Retain

    Keep the ampule and the syringe

  4. Report

    FDA Philippines ADR report, plus the distributor channel

  5. Correlate

    Reproducible? Same lot, same hands, same day?

Until that is done, the drug has been convicted without a trial.

No batch retained. No lot number recorded. No report filed. Absence of data is not evidence of quality; it is absence of investigation.

Stop Blaming the Baricity|Lecture re-echo|What to do13 / 15

Take-home messages

1

It’s the technique, not the brand

Failed spinals are common, and happen with every manufacturer’s bupivacaine.

2

Four failure points are ours

Needle, dose, spread and assessment all come before the drug.

3

Check before you repeat

Run the checklist, test with touch, ask the patient. Never repeat a full dose blindly.

4

Suspect the drug? Investigate

Record, quarantine, retain, report, correlate.

Stop Blaming the Baricity|Lecture re-echo|Take-home14 / 15

References

As cited on the lecture slides

  1. Fettes PDW, Jansson JR, Wildsmith JAW. Failed spinal anaesthesia: mechanisms, management, and prevention. Br J Anaesth. 2009;102(6):739–48.
  2. Hocking G, Wildsmith JAW. Intrathecal drug spread. Br J Anaesth. 2004;93(4):568–78.
  3. Plaat et al. Anaesthesia. 2022.
  4. Kampe et al. Anesth Analg. 2003;96:1234.
  5. Bayable et al. Ann Med Surg. 2022.
  6. Jin et al. Anesth Analg (year partly hidden).
  7. … & Habib. Curr Opin Anaesthesiol. 2024 (author partly hidden).
  8. … et al. Int J Surg Open. 2020 (author partly hidden).
  9. OAA / AAGBI guidance on failed and inadequate neuraxial block.